Industrial Turbine: Difference between revisions

(Drastically simplified and explained the flow rate equation. It's much simpler than it looks.)
mNo edit summary
Line 61: Line 61:
      
      
     MAX_RATE = min(TURBINE_DISPERSER_COUNT * GENERAL_DISPERSER_GAS_FLOW * structure.lowerVolume, TURBINE_VENT_COUNT * GENERAL_VENT_GAS_FLOW)
     MAX_RATE = min(TURBINE_DISPERSER_COUNT * GENERAL_DISPERSER_GAS_FLOW * structure.lowerVolume, TURBINE_VENT_COUNT * GENERAL_VENT_GAS_FLOW)
     FLOW = min(1, TURBINE_STORED_AMOUNT / MAX_RATE) * (TURBINE_STORED_AMOUNT/TURBINE_MAX_STORED_AMOUNT)
     FLOW = min(1, TURBINE_STORED_AMOUNT / MAX_RATE) * (TURBINE_STORED_AMOUNT/TURBINE_MAX_STORED_AMOUNT) * MAX_RATE


==Miscellaneous Notes==
==Miscellaneous Notes==

Revision as of 19:31, 10 December 2023

New in v9 is the Turbine Multiblock. This massive structure is used to produce power from the reactor that was introduced with v8.

Video Tutorials

https://www.youtube.com/watch?v=9EgZTwCnWwA&t - EsquilãoBR Tutorial PT-BR

https://www.youtube.com/watch?v=vrwz3j--Vcs - Tutorial Made by MathewCell

https://www.youtube.com/watch?v=kHJSEUjCsyA - Tutorial Made by AidancBrady

Components

Construction Notes

  • Orientation can only be vertical (Unlike BR's turbine)
  • Length and Width (x,z) must be equal.
  • Maximum shaft height = min(2xLENGTH-5,14) [so blades don't touch sides]
  • Maximum total height = min(2xLENGTH-1,18)
  • Tank volume = LENGTH^2xROTOR_HEIGHT
  • Flow rate is determined by tank volume times dispersers (exact formula inside notes) or by vents - whichever is less. Each vent adds 32,000mB/t of flow rate, and each disperser can disperse 1,280mB/t of flow per block of interior volume.
  • Energy production = FLOWxROTOR_HEIGHTx50RF/7
  • Because a taller rotor leaves less room for vents, sometimes heightening the rotor could reduce flow and, therefore, energy.
  • 1 coil will support 4 blades. You'll never need more than 7 coils.
  • Interior may ONLY be dispersers, coils, shaft, blades, rotational complex, or air.
  • Multiblock will sparkle red on final block placement, otherwise check your assembly.
  • Minimal turbine size is 5x5 base with 5 blocks high.
  • Maximum turbine size is 17x17 base with 18 blocks high.

Construction steps

  1. Build the base out of turbine casings and optional structural glass. (must be square) [the perimeter must be casings not glass]
  2. Place rotor shafts in the center, from the base to desired height.
  3. Add turbine blades to the rotor. (two for each rotor shaft)
  4. Place a rotational complex on top of the rotor.
  5. Completely fill the interior layer around the rotational complex with pressure dispersers.
  6. Place electromagnetic coils above the dispersers. They must touch the rotational complex and each other.
  7. Build the frame (the perimeters of the walls) out of turbine casings. (you may have more empty layers above the coils to make room for more vents)
  8. Fill the walls, up to the height of the rotor, with turbine casings and/or structural glass and at least 2 turbine valves.
  9. Fill the remaining walls and ceiling with turbine casings and/or turbine vents.

Flow Rate

  • The "flow rate" is really an efficiency ratio: it measures how much of your turbine's maximum output you're actually getting. It can never be larger than 1.
  • The actual maximum rate of steam flow (labeled MAX_RATE below) is limited by both the number of dispersers and the number of vents. Each vent can pass 32,000 mB/t; each disperser can disperse 1,280 mB/t *per block of interior volume*.
    • "Interior volume" -- labeled `structure.lowerVolume` below -- means the inside volume of the rotor chamber. So if your base is 11x11 and you have 4 blocks of rotor shaft, then your interior volume is 9x9x4=324 blocks, and every disperser disperses 414,720 mB/t.
  • The flow rate is the product of two numbers:
    • The fill ratio of the turbine: (volume of steam)/(maximum volume of steam)
    • The current rate of steam flow, as a fraction of MAX_RATE. Ideally this would just be 1, but you can't move more steam than is actually in your turbine -- so if (volume of steam) < MAX_RATE, you only get (volume of steam)/MAX_RATE.
  • In addition, the actual energy gained per tick is capped by the energy storage of the turbine.
  • As long as you have room to put the energy, the equation is just:
   GENERAL_DISPERSER_GAS_FLOW = 1280
   GENERAL_VENT_GAS_FLOW = 32000
   
   MAX_RATE = min(TURBINE_DISPERSER_COUNT * GENERAL_DISPERSER_GAS_FLOW * structure.lowerVolume, TURBINE_VENT_COUNT * GENERAL_VENT_GAS_FLOW)
   FLOW = min(1, TURBINE_STORED_AMOUNT / MAX_RATE) * (TURBINE_STORED_AMOUNT/TURBINE_MAX_STORED_AMOUNT) * MAX_RATE

Miscellaneous Notes

  • Compatible with oredict steam from other mods such as TE/TF/RC/MFR/Big Reactors.
  • The marking of "Limiting" on the vents stat simply means that it is not "optimal ratio". You can have fewer down to your desired steam flow rate.
  • Turbine shuts down if internal battery fills with energy. It will restart automatically though you may also vent excess steam to prevent it from shutting down.
  • A 5x5x8 turbine design will produce the exact same RF/t as the highest tiered turbine from Big Reactors with the same amount of steam.

Images

Detailed interior of a 7x7x10
Main interface showing power production and steam consumption
Statistics page showing turbine construction stats


Cookies help us deliver our services. By using our services, you agree to our use of cookies.

Need wiki hosting?

Do you need a wiki for your Minecraft mod/gaming wiki? We'll host it for free! Contact us.

Other wikis

Indie-game wikis
Powered by Indie Wikis