Industrial Turbine
New in v9 is the Turbine Multiblock. This massive structure is used to produce power from the reactor that was introduced with v8.
Components
- Turbine Casing
- Turbine Vent
- Pressure Disperser
- Turbine Blades
- Turbine Rotor
- Rotational Complex
- Electromagnetic Coil
- Turbine Valve
- Structural Glass (Optional)
Construction Notes
- Orientation can only be vertical (Unlike BR's turbine)
- Length and Width (x,z) must be equal.
- Maximum shaft height = min(2xLength-5,14) [so blades don't touch sides]
- Maximum total height = min(2xLength-1,18)
- The layer of pressure dispersers must completely fill the interior layer around the rotational complex.
- 1 coil will support 4 blades.
- Interior may ONLY be steam dispersers, coils, shaft, blades, rotational complex, or air.
- Vents limit the max flow of steam through the turbine. Each vent adds 16,000mB/t of flow rate.
- The marking of "Limiting" on the vents stat simply means that it is not "optimal ratio". You can have fewer down to your desired steam flow rate.
- Multiblock will sparkle red on final block placement, otherwise check your assembly.
- Minimal turbine size is 5x5 base with 5 blocks high.
- Maximum turbine size is 17x17 base with 18 blocks high, 28 turbine blades maximum.
- Compatible with oredict steam from other mods such as TE/TF/RC/MFR/Big Reactors.
Operation Notes
- Turbine shuts down if internal battery fills with energy. Make sure the power is always being used.
- New change to the industrial turbine is that it allows you to vent excess steam to prevent it from shutting down (Option not shown).
Miscellaneous Notes
- A 5x5x8 turbine design will produce the exact same RF/t as the highest tiered turbine from Big Reactors with the same amount of steam.
- Extra coils appear to have no effect unless it's "limiting". Extending the turbine is next logical step if more power needed.
Construction steps
- Build the base out of turbine casings.
- Build the frame out of turbine casings(the corners of the walls)
- Build the ceiling of the turbine, make sure to include turbine vents.
- Place rotor shafts from the "floor" to two blocks under the ceiling to leave room for electromagnetic coils and pressure dispersers.
- Fill the next layer with pressure dispersers, and place a rotational complex in the middle.
- Finally, place electromagnetic coils in the next layer, they can be in any arrangement as long as they're touching the rotational complex and each other.
Images
![]() |
![]() |
![]() |
Cookies help us deliver our services. By using our services, you agree to our use of cookies.