Industrial Turbine: Difference between revisions
No edit summary |
No edit summary |
||
Line 16: | Line 16: | ||
* Orientation can only be vertical (Unlike BR's turbine) | * Orientation can only be vertical (Unlike BR's turbine) | ||
* Length and Width (x,z) must be equal. | * Length and Width (x,z) must be equal. | ||
* Maximum shaft height = min( | * Maximum shaft height = min(2xLENGTH-5,14) [so blades don't touch sides] | ||
* Maximum total height = min( | * Maximum total height = min(2xLENGTH-1,18) | ||
* | * Tank volume = LENGTH^2xROTOR_HEIGHTx64,000mB | ||
* 1 coil will support 4 blades. | * Flow rate is determined by tank volume (formula unknown) and vents, whichever is less. Each vent adds 16,000mB/t of flow rate. | ||
* Interior may ONLY be | * Energy production = FLOWxROTOR_HEIGHTx50RF/7 | ||
* Because a taller rotor leaves less room for vents, sometimes heightening the rotor could reduce flow and, therefore, energy. | |||
* 1 coil will support 4 blades. You'll never need more than 8 coils. | |||
* Interior may ONLY be dispersers, coils, shaft, blades, rotational complex, or air. | |||
* Multiblock will sparkle red on final block placement, otherwise check your assembly. | * Multiblock will sparkle red on final block placement, otherwise check your assembly. | ||
* Minimal turbine size is 5x5 base with 5 blocks high. | * Minimal turbine size is 5x5 base with 5 blocks high. | ||
* Maximum turbine size is 17x17 base with 18 blocks high | * Maximum turbine size is 17x17 base with 18 blocks high. | ||
==Construction steps== | ==Construction steps== | ||
Line 34: | Line 34: | ||
# Place a rotational complex on top of the rotor. | # Place a rotational complex on top of the rotor. | ||
# Completely fill the interior layer around the rotational complex with pressure dispersers. | # Completely fill the interior layer around the rotational complex with pressure dispersers. | ||
# Place electromagnetic coils above the dispersers | # Place electromagnetic coils above the dispersers. They must touch the rotational complex and each other. | ||
# Build the frame (the perimeters of the walls) out of turbine casings. (you may have more empty layers above the coils to make room for more vents) | # Build the frame (the perimeters of the walls) out of turbine casings. (you may have more empty layers above the coils to make room for more vents) | ||
# Fill the walls, up to the height of the rotor, with turbine casings and/or structural glass and at least 2 turbine valves. | # Fill the walls, up to the height of the rotor, with turbine casings and/or structural glass and at least 2 turbine valves. | ||
# Fill the remaining walls and ceiling with turbine casings and/or turbine vents. | # Fill the remaining walls and ceiling with turbine casings and/or turbine vents. | ||
==Miscellaneous Notes== | ==Miscellaneous Notes== | ||
* Compatible with oredict steam from other mods such as TE/TF/RC/MFR/Big Reactors. | |||
* The marking of "Limiting" on the vents stat simply means that it is not "optimal ratio". You can have fewer down to your desired steam flow rate. | |||
* Turbine shuts down if internal battery fills with energy. It will restart automatically though you may also vent excess steam to prevent it from shutting down. | |||
* A 5x5x8 turbine design will produce the exact same RF/t as the highest tiered turbine from Big Reactors with the same amount of steam. | * A 5x5x8 turbine design will produce the exact same RF/t as the highest tiered turbine from Big Reactors with the same amount of steam. | ||
==Images== | ==Images== |
Revision as of 12:26, 2 February 2018
New in v9 is the Turbine Multiblock. This massive structure is used to produce power from the reactor that was introduced with v8.
Components
- Turbine Casing
- Turbine Vent
- Pressure Disperser
- Turbine Blades
- Turbine Rotor
- Rotational Complex
- Electromagnetic Coil
- Turbine Valve
- Structural Glass (Optional)
Construction Notes
- Orientation can only be vertical (Unlike BR's turbine)
- Length and Width (x,z) must be equal.
- Maximum shaft height = min(2xLENGTH-5,14) [so blades don't touch sides]
- Maximum total height = min(2xLENGTH-1,18)
- Tank volume = LENGTH^2xROTOR_HEIGHTx64,000mB
- Flow rate is determined by tank volume (formula unknown) and vents, whichever is less. Each vent adds 16,000mB/t of flow rate.
- Energy production = FLOWxROTOR_HEIGHTx50RF/7
- Because a taller rotor leaves less room for vents, sometimes heightening the rotor could reduce flow and, therefore, energy.
- 1 coil will support 4 blades. You'll never need more than 8 coils.
- Interior may ONLY be dispersers, coils, shaft, blades, rotational complex, or air.
- Multiblock will sparkle red on final block placement, otherwise check your assembly.
- Minimal turbine size is 5x5 base with 5 blocks high.
- Maximum turbine size is 17x17 base with 18 blocks high.
Construction steps
- Build the base out of turbine casings and optional structural glass. (must be square) [the perimeter must be casings not glass]
- Place rotor shafts in the center, from the base to desired height.
- Add turbine blades to the rotor. (two for each rotor shaft)
- Place a rotational complex on top of the rotor.
- Completely fill the interior layer around the rotational complex with pressure dispersers.
- Place electromagnetic coils above the dispersers. They must touch the rotational complex and each other.
- Build the frame (the perimeters of the walls) out of turbine casings. (you may have more empty layers above the coils to make room for more vents)
- Fill the walls, up to the height of the rotor, with turbine casings and/or structural glass and at least 2 turbine valves.
- Fill the remaining walls and ceiling with turbine casings and/or turbine vents.
Miscellaneous Notes
- Compatible with oredict steam from other mods such as TE/TF/RC/MFR/Big Reactors.
- The marking of "Limiting" on the vents stat simply means that it is not "optimal ratio". You can have fewer down to your desired steam flow rate.
- Turbine shuts down if internal battery fills with energy. It will restart automatically though you may also vent excess steam to prevent it from shutting down.
- A 5x5x8 turbine design will produce the exact same RF/t as the highest tiered turbine from Big Reactors with the same amount of steam.
Images
![]() |
![]() |
![]() |
Cookies help us deliver our services. By using our services, you agree to our use of cookies.